What Size Aircon Do I Need? (South African Guide)

Work it out from floor area: a typical South African room needs about 450 BTU per square metre, so a 20 m² room lands on 9000–12000 BTU once sun and occupancy are counted. Measure the room, apply the adjustments below, then round up to the nearest standard size.

Updated 22 November 2026 7 min read
Base rule
450 BTU per m²
20 m² room
9000–12000 BTU
25 m² room
12000–18000 BTU
35 m² room
18000 BTU
50 m² room
24000 BTU
Rule of thumb
Round up, never down

The method below is the one we use on site before quoting, minus the measurements a technician takes. It is deliberately simple: four steps, then a table, then a calculator that does the arithmetic for you.

Step 1 — measure the floor area

Length × width in metres. Measure the room itself, not the whole house divided by the number of rooms. If the room is L-shaped, split it into rectangles and add them. If it opens into another room with no door, measure both — the air does not stop at the threshold.

Step 2 — apply the base load

Multiply the area by 450 BTU. That figure assumes a 2.4 m ceiling, average windows and two occupants — the typical South African bedroom or lounge. A 20 m² room gives 9000 BTU; a 30 m² room gives 13500 BTU.

Step 3 — adjust for the room

FactorAdjustmentWhy
Ceiling height× (height ÷ 2.4), up to 1.5You are cooling volume, not floor
Low sun / shaded× 0.90Less radiant heat through glass
High sun / west-facing glass× 1.15Afternoon sun is the worst case
Bedroom× 0.95Fewer people, less equipment
Lounge / living× 1.05People, TVs, more airflow between rooms
Kitchen× 1.15Stove, oven, fridge, dishwasher
Top floor / no roof insulation+10%Ceiling heat gain
Poor wall or window insulation+10%Heat leaks back in
Each person above two+400 BTUPeople are 400 BTU each
Apply the factors in any order — they multiply. A west-facing top-floor lounge with four people can need double the base load of a shaded bedroom of the same size.

Step 4 — round up to a standard size

Standard split sizes and the rooms they suit
Standard aircon sizes with cooling capacity in kW, floor area in square metres and square feet
BTU kW m² ft² Typical room
9,000 2.6 18.9 204 Small bedroom, study, flatlet
12,000 3.5 25.3 272 Main bedroom, small lounge, office
18,000 5.3 37.9 408 Lounge, open-plan living, small shop
24,000 7.0 50.5 544 Large open-plan living, boardroom
30,000 8.8 63.2 680 Open-plan house, small restaurant
36,000 10.6 75.8 816 Large open-plan or commercial space
48,000 14.1 101.1 1,088 Shop, office suite, small hall
60,000 17.6 126.3 1,360 Commercial space — assessment required

Never round down to save money. An aircon that is 10% too small runs at 100% duty forever; one that is 10% too large runs in short bursts. The first costs more in electricity and wears out faster. If your calculation lands exactly between two sizes, take the larger one — except in a bedroom, where the smaller unit will be quieter and less prone to short-cycling.

Does ceiling height really matter?

Yes, and it is the adjustment people skip. A 25 m² room with a 2.4 m ceiling holds 60 m³ of air. The same room with a 3.6 m raked ceiling holds 90 m³. That is 50% more air to cool, and a high-wall unit mounted at 2.4 m will struggle to push cool air down into the occupied zone. Our calculator scales for this automatically.

Aircon size calculator

Room measurements
Measurements

Recommended size

12,000BTU

≈ 3.5 kW · 20.0 m² (215 ft²)

A 20.0 m² lounge / living room with a 2.4 m ceiling, medium sun and 2 people needs about 9,500 BTU. We recommend the nearest standard size up: 12,000 BTU (3.5 kW), which is the size we would quote for this room.

Get a quote for a 12,000 BTU unit
How we got this number
Floor area
20.0 m² (215.3 ft²)
Base load at 450 BTU/m²
9,000 BTU
Room type — Lounge / living room
× 1.05
Calculated duty
9,500 BTU

Based on 450 BTU/m², adjusted for ceiling height, sun, room type and occupancy. A site assessment confirms the final size.

BTU, kW or tons — which number do I use?

They are the same capacity in different units. 12000 BTU = 3.5 kW = 1 ton. South African retailers mostly advertise BTU, installers talk kW, and imported equipment sometimes uses tons. If a quote gives you kW, multiply by 3412 to compare it with a BTU price. Our converter does it both ways.

Not sure? Send us the room and we will size it

Tell us the length, width, ceiling height, window direction and town. We will confirm the size in writing before you commit to anything.

Size by size

Frequently asked questions

How do I calculate what size aircon I need?

Multiply floor area in m² by 450 BTU, then adjust for ceiling height, sun, room type, people and insulation. Round up to the nearest standard size: 9000, 12000, 18000, 24000 or 30000 BTU.

Is a bigger aircon always better?

No. An oversized unit cools the air quickly then switches off, leaving the room clammy because it never runs long enough to remove moisture. It also short-cycles, which is harder on the compressor than steady running.

Does ceiling height affect aircon size?

Yes. Capacity follows air volume, not floor area. A 3.6 m ceiling holds 50% more air than a 2.4 m ceiling over the same floor, so the unit needs proportionally more capacity.

What size aircon for a 40 m² room?

About 18000–24000 BTU depending on ceiling, glazing and occupancy. A shaded 40 m² bedroom sits near 18000; a west-facing open-plan living area of the same size needs 24000.

How many BTU per square metre in South Africa?

About 450 BTU per m² as a base, adjusted upwards for high ceilings, west-facing glass, kitchens, top floors and extra people. It is a starting point, not a substitute for measuring the room.