Aircon Leaking Water: 6 Causes and What to Check First
Water dripping from an aircon is usually a blocked drain or a frozen coil. Here are the six causes, what you can check safely, and when to call.
Why an aircon produces water at all
An air conditioner does not just cool air, it dries it. Moisture from the room condenses on the cold indoor coil, drips into a shallow tray under the coil, and leaves through a drain pipe. In a humid Eastern Cape summer a wall split can pull several litres a day out of a room, which is exactly what you want — as long as it leaves the building.
When water appears where it should not — down the wall, out of the louvres, dripping onto a bed or a desk — the system is still doing its job. What has failed is the route the water takes to get out. That is why a leak is rarely a sign that the unit is finished; it is usually a sign that something is blocked, frozen or no longer sloping the right way.
One warning before anything else: if water is anywhere near a plug point, a light fitting or a ceiling, switch the unit off at the isolator and leave it off. Water and 230 volts do not mix, and a ceiling that is bulging is a call-out, not a look-and-see.
1. A blocked condensate drain — the cause in most cases
The drain pipe is narrow, permanently wet and open to the air, which makes it a perfect home for algae and biofilm. Over a season it coats the inside of the pipe until the flow slows to a trickle, then stops. The tray fills, and the water finds the next lowest point: usually the wall or the floor.
Dust makes it worse. In a house near a gravel road, on a farm, or in a room with building work going on, the tray itself silts up and the outlet clogs from the inside.
This is the single most common aircon fault we are called to, and it is also the cheapest to prevent: a drain flush is part of every proper service, and on the coast it should happen at least once a year.
2. A dirty filter freezing the coil
When the return-air filter is clogged, the unit keeps cooling but the air cannot carry the heat away from the coil. The coil temperature drops below freezing, ice forms, and when that ice melts overnight you get a puddle that looks like a leak but is really a blocked filter.
The tell-tale is ice on the indoor unit or the pipework, and a unit that seems to be running but not cooling. A filter rinse takes a few minutes and should be done monthly in summer — it is the one maintenance task worth doing yourself.
3. Low refrigerant or a restricted circuit
A system that is low on gas can ice up in the same way, because the pressure in the evaporator drops and the coil runs colder than it should. This one does not fix itself, and topping up the gas without finding the leak is money spent twice: the gas escapes again, and the compressor runs undercharged in the meantime.
If the unit ices up repeatedly after a filter clean, the next step is a pressure test and a leak check — not another top-up.
4. The unit is no longer sitting level
The drain tray relies on gravity. If the indoor unit has been knocked, mounted on a wall that has settled, or installed with a slight backward tilt, water pools at the wrong end and spills over the lip instead of running out of the drain.
You can see this from the ground: hold a spirit level under the indoor unit, or look at where the water collects. A unit that leaks only at the far end of the tray is telling you it is out of level.
5. A disconnected, cracked or badly routed drain
Drains get pulled, stood on and pinched. A pipe that has come off the tray spigot, a cracked elbow behind the trunking, or a drain that has been routed uphill into a gutter will all put water inside the building.
This is also where cheap installations show themselves: a drain that runs into the flower bed instead of a proper outlet will soak the foundation, and a drain that has no fall will block within a season.
6. A failed condensate pump on a ducted or cassette system
Where there is no gravity route out — a cassette in an internal ceiling, a ducted unit in a roof void — the water is lifted by a small pump. Pumps fail quietly, and when they do, the tray overflows into the ceiling.
A ceiling stain, a musty smell in a room with no obvious damp, or a dripping sound above the ceiling are all pump symptoms. These need a technician because the equipment is not accessible without opening the ceiling.
What you can safely check yourself
Rinse the filter and look at the coil for ice. Check that the drain outlet outside is actually running water when the unit is on, and that it is not dribbling onto a path that runs back to the wall. Look at the indoor unit from below for a tilt, and check whether the leak happens only on humid days or after long runs.
Switch it off if water is near electrics, and do not keep running a unit that is icing up. Beyond that, the useful checks need the covers off and a pressure gauge.
When it is worth calling someone
Call if the unit has leaked twice after a filter clean, if there is ice on the coil, if the water is anywhere near a ceiling, light or socket, or if there is a musty smell that does not go away. A leak that returns within days is a symptom, not a one-off.
A proper call-out is a drain flush and test, a coil and filter clean, a check of the tray and drain route, and a pressure and electrical check while the covers are off. That finds the cause instead of mopping up after it — and it is also the point at which we tell you honestly if the repair is not worth doing.